Technical Knowledge
In an HVAC installation, the system must move heat from indoor air to the outdoors.
Describe the refrigeration cycle that enables this heat transfer.
I explained that the cycle consists of four main stages: compression of low‑pressure refrigerant gas in the compressor, condensation where the high‑pressure gas releases heat to the outdoor air, expansion through an expansion valve causing a pressure drop and temperature drop, and evaporation where the low‑pressure liquid absorbs indoor heat.
The interviewer understood that I could clearly articulate the cycle and its relevance to system performance.
- Can you describe how a refrigerant leak impacts system performance?
- What tools would you use to diagnose a low‑pressure issue?
- Accurate description of each stage
- Correct terminology (compressor, condenser, expansion valve, evaporator)
- Clear link to heat transfer in HVAC
- Mixing up condenser and evaporator functions
- Omitting the expansion valve step
- Compress refrigerant gas → high pressure
- Condense in outdoor coil → release heat
- Expand through valve → temperature drop
- Evaporate in indoor coil → absorb heat
A homeowner was deciding between a split system and a packaged unit for a new build.
Explain the main differences to help the customer choose.
I highlighted that split systems have separate indoor and outdoor units, offering flexibility in zoning and quieter indoor operation, while packaged units house all components in a single outdoor cabinet, saving indoor space and simplifying installation.
The customer appreciated the clear comparison and selected the option that best fit their space constraints.
- Which system would you recommend for a small commercial building and why?
- How does maintenance differ between the two types?
- Clarity of comparison
- Mention of zoning, space, noise, and installation factors
- Accurate terminology
- Stating that split systems are always more expensive without context
- Ignoring maintenance considerations
- Split system: indoor & outdoor units, better zoning, quieter indoors
- Packaged unit: all components in one outdoor cabinet, saves indoor space, quicker install
During a new installation, the system was underperforming after initial startup.
Identify the proper refrigerant charge to restore performance.
I consulted the manufacturer’s data sheet for the specific model, used the superheat and subcooling method with accurate temperature and pressure readings, and adjusted the charge until the superheat was within the recommended range.
System efficiency returned to design specifications, and the client reported consistent temperature control.
- What instruments are essential for measuring superheat and subcooling?
- How would you handle a system that uses R‑410A versus R‑22?
- Reference to manufacturer specs
- Correct use of superheat/subcooling calculations
- Safety precautions when handling refrigerants
- Guessing charge without measurements
- Ignoring safety protocols
- Reference manufacturer data sheet
- Measure suction and discharge pressures
- Calculate superheat/subcooling
- Adjust charge accordingly
Safety & Regulations
While servicing a commercial rooftop unit, I needed to recover refrigerant.
Select and use appropriate PPE to ensure safety and compliance.
I wore safety goggles, chemical‑resistant gloves, a face shield, and a certified respirator when the refrigerant was toxic. I also used insulated gloves for cold surfaces and steel‑toed boots for fall protection.
The job was completed without injury or exposure, and the work complied with OSHA and EPA regulations.
- How do you verify that your PPE is still effective before a job?
- What steps do you take if a refrigerant leak occurs during service?
- Complete PPE list
- Reference to OSHA/EPA standards
- Explanation of why each item is needed
- Omitting respirator when required
- Neglecting fall protection
- Safety goggles
- Chemical‑resistant gloves
- Face shield
- Certified respirator (if needed)
- Insulated gloves for cold surfaces
- Steel‑toed boots
A new hire needed to be qualified to work on refrigerants in my shop.
Explain the certification levels and renewal process.
I outlined the four types of Section 608 certifications—Type I (small appliances), Type II (high‑pressure appliances), Type III (low‑pressure appliances), and Universal (all types). I noted the exam requirements, record‑keeping of refrigerant usage, and the need for recertification every three years.
The new hire completed the appropriate exam, received the Universal certification, and our shop remained compliant with EPA regulations.
- What penalties can a company face for non‑compliance with Section 608?
- How do you stay updated on changes to refrigerant regulations?
- Accurate description of certification types
- Mention of record‑keeping and renewal
- Awareness of regulatory consequences
- Confusing Type II and Type III scopes
- Omitting recertification requirement
- Four certification types (I, II, III, Universal)
- Exam content and passing score
- Record‑keeping of refrigerant purchases
- Three‑year recertification
I needed to service a rooftop HVAC unit on a commercial building.
Follow ladder safety protocols to prevent falls.
I inspected the ladder for defects, positioned it at a 75‑degree angle, secured the base, used a ladder stabilizer, maintained three points of contact, and never exceeded the ladder’s weight rating. I also wore a harness attached to a secure anchor point.
The service was completed without incident, and the client praised the professionalism and safety focus.
- How would you handle a situation where the roof surface is uneven?
- What alternative access methods exist for rooftop units?
- Clear safety steps
- Reference to OSHA ladder standards
- Use of personal fall arrest system when needed
- Skipping inspection
- Overreaching while on ladder
- Inspect ladder condition
- Set angle to 75 degrees
- Secure base and use stabilizer
- Maintain three points of contact
- Observe weight limit
- Use harness when required
Customer Service & Problem Solving
A homeowner reported hot spots on the second floor after a recent HVAC installation.
Identify the cause of uneven cooling and propose a solution.
I asked detailed questions about thermostat settings, airflow, and recent changes. I inspected ductwork for leaks, checked for closed registers, measured temperature differentials, and verified proper refrigerant charge. I discovered an unbalanced duct and a dirty air filter.
After sealing the duct leak and replacing the filter, the home achieved consistent temperatures, and the customer expressed satisfaction with the thorough service.
- What tools would you use to locate a hidden duct leak?
- How do you explain the importance of regular filter changes to the homeowner?
- Systematic diagnostic approach
- Effective communication with customer
- Identification of root cause
- Jumping to conclusions without inspection
- Blaming the customer without evidence
- Gather detailed symptom info
- Check thermostat settings
- Inspect ductwork for leaks or disconnections
- Verify all registers are open
- Measure temperature differentials
- Check refrigerant charge and filter condition
A client called angry because their heating system failed during a cold snap and our technician was running late.
De‑escalate the situation and maintain the client’s trust.
I listened actively, apologized sincerely, explained the cause of the delay (traffic due to an accident), offered a revised arrival window, and provided a complimentary system check for future maintenance. I also arranged a discount on the current service as goodwill.
The client calmed down, appreciated the transparency, and agreed to the new appointment time, resulting in a completed repair and positive feedback.
- What policies would you implement to minimize future delays?
- How do you document the interaction for future reference?
- Empathy and active listening
- Clear explanation and realistic ETA
- Offer of compensation or added value
- Deflecting blame
- Providing vague or unrealistic timeframes
- Listen without interrupting
- Apologize sincerely
- Explain reason for delay
- Provide new ETA
- Offer compensation or added value
A commercial office building’s HVAC system was short‑cycling, causing temperature swings and high energy bills.
Diagnose the root cause and implement a lasting fix.
I reviewed the control logs, inspected the thermostat wiring, and measured refrigerant pressures. I discovered a faulty pressure switch that shut the compressor off prematurely. I replaced the switch, recalibrated the thermostat, and verified proper airflow after cleaning the coils.
The system operated continuously without short‑cycling, reducing energy consumption by 12% and restoring occupant comfort.
- What preventive maintenance can reduce short‑cycling incidents?
- How would you explain the issue to a non‑technical building manager?
- Logical step‑by‑step troubleshooting
- Identification of correct faulty component
- Verification of solution effectiveness
- Skipping data log review
- Replacing parts without testing
- Review control logs and error codes
- Inspect thermostat and wiring
- Measure refrigerant pressures
- Identify faulty components (e.g., pressure switch)
- Replace defective part and recalibrate controls
- Verify airflow and system performance
During a service call, the homeowner asked how to reduce their monthly energy bill.
Communicate the advantages of upgrading to a programmable thermostat.
I highlighted that a programmable thermostat can automatically lower heating or cooling during unoccupied hours, set optimal temperature setbacks, and provide usage reports. I gave a simple example showing a potential 10‑15% savings based on their current usage patterns.
The homeowner decided to purchase and install the programmable thermostat, later reporting lower utility bills.
- Can you walk the homeowner through setting a weekday schedule?
- What incentives or rebates might be available for smart thermostats?
- Clear, jargon‑free explanation
- Quantified savings estimate
- Focus on homeowner’s cost concerns
- Using technical jargon without explanation
- Overpromising savings
- Automatic temperature setbacks
- Scheduling based on occupancy
- Energy usage reports
- Potential savings estimate
Teamwork & Leadership
A new technician struggled to locate a refrigerant leak in a multi‑zone system.
Guide them through a systematic leak detection process.
I paired with the junior, reviewed the system schematics, demonstrated the use of an electronic leak detector, and walked them through checking each zone’s pressure readings. I encouraged them to document findings and ask questions throughout.
The junior successfully identified the leak, repaired it, and gained confidence in handling future diagnostics.
- How do you assess when a junior is ready for independent work?
- What feedback method do you use after a joint task?
- Patience and clear instruction
- Encouragement of critical thinking
- Successful resolution of the issue
- Taking over the task completely
- Providing vague instructions
- Review schematics together
- Demonstrate leak detection tool
- Step‑by‑step pressure checks
- Encourage documentation and questions
Our service department received five emergency calls on a Monday morning, including a gas leak and a broken chiller.
Create a priority schedule that addresses urgency, safety, and resource allocation.
I assessed each call’s severity, assigning the gas leak as highest priority due to safety, the chiller next for business impact, then routine maintenance calls. I dispatched technicians with appropriate certifications, ensured each had the required PPE, and communicated clear arrival windows to customers.
All high‑risk issues were resolved within the required timeframes, no safety incidents occurred, and customer satisfaction scores remained high.
- What tools do you use to track and update job statuses in real time?
- How would you handle a sudden staff shortage mid‑day?
- Logical risk‑based prioritization
- Consideration of technician skill set
- Clear communication plan
- Prioritizing based on distance alone
- Ignoring safety certifications
- Assess severity and safety risk
- Rank calls by impact
- Match technicians to required skills and certifications
- Ensure PPE and safety briefings
- Communicate ETAs to customers
- HVAC maintenance
- troubleshooting
- EPA Section 608
- refrigerant handling
- ductwork inspection
- customer service